A complete GxP ecosystem.
Let’s digitize your plant
Quality, laboratory, production, cleanrooms, archives, validation: six applications for pharmaceutical sites, built on the same data integrity principles.
Drag to rotate the model, then choose a building. Tap a building to open its fact sheet.
One building per function
Each application has its own building and can be used alone or with the others.
-
QaLyZa eQMS
The quality office
Discover the eQMS15 modules that cover every aspect of GMP, including change control, deviations, EDMS and training.
-
QaLyZa LIMS
The laboratory
Discover the LIMSThe quality control laboratory, day to day, from sample receipt to the certificate of analysis.
-
QaLyZa MES
The production plant
Discover the MESThe electronic batch record, executed on a tablet right at the line, through to batch release.
-
QaLyZa EMS
The controlled environment area
Discover the EMSMonitoring of your controlled environment areas, grades A to D: samples, sensors and excursions.
-
QaLyZa AMS
The archives
Discover the AMSQalyza scans and stores your paper documents; you view them remotely, on a web portal.
-
QaLyZa VMS
The validation department
Discover the VMSPaperless qualification and validation: protocols, manufacturing processes and statistics, from drafting to approval.
-
Lya
The server room, at the foot of the quality office
Discover LyaThe eQMS AI assistant: your teams ask it their questions, and it answers from your server.
What flows between the buildings
All the applications are interconnected. On the model, each exchange follows its own glowing path.
-
ERP to MES
Manufacturing orders.
-
Scales to MES
Weighings.
-
OPC UA to MES
Process values from the equipment.
-
LIMS to MES
Test results.
-
EMS to eQMS
An excursion raised as a deviation.
-
MES to eQMS
Batch deviations, with their progress reported back.
-
LIMS and eQMS
Laboratory and quality data, in both directions.
-
AMS and eQMS
Quality documents and their archives, in both directions.
-
VMS and eQMS
Validations and quality records, in both directions.
Each GMP process has its own module
Good Manufacturing Practice (GMP) describes the processes of a pharmaceutical site. Each one is supported by a module, in one of the site's buildings.
| GMP process | In QaLyZa |
|---|---|
| Change controlICH Q10, EU GMP Chapter 1 |
|
| Deviations, corrective and preventive actionsICH Q10 |
|
| Out-of-specification resultsEU GMP Chapter 6, 2022 FDA OOS guidance |
|
| Complaints and recallsEU GMP Chapter 8 |
|
| Self-inspections and auditsEU GMP Chapter 9 |
|
| DocumentationEU GMP Chapter 4 |
|
| Personnel and trainingEU GMP Chapter 2 |
|
| Qualification and validationEU GMP Annex 15 |
|
| Quality risk managementICH Q9 |
|
| Premises, equipment and calibrationEU GMP Chapter 3 |
|
| SuppliersEU GMP Chapters 5 and 7 |
|
| Production and batch recordsEU GMP Chapters 4 and 5 |
|
| Quality controlEU GMP Chapter 6 |
|
| Sterile medicinal products, environmental monitoringEU GMP Annex 1 |
|
| Computerized systemsEU GMP Annex 11, 21 CFR Part 11 |
|
The eQMS validation package is provided
Following the risk-based GAMP 5 approach. The eQMS validation package is delivered in French and English, with a kit for your team.
The MES comes with a validation readiness checklist. The LIMS and the EMS document their traceability matrices, from requirement to test.
The documents in the eQMS validation package
- Validation plan
- Specifications: user requirements, functions, design
- Risk assessment
- IQ, OQ and PQ qualification protocols
- Traceability matrix
- Validation report
- Kit for your team: guide, URS template, customer protocols
The standards, sheet by sheet
There is no Part 11 or Annex 11 certification for software: these texts apply to your organization. Each sheet describes the mechanisms QaLyZa implements to help you demonstrate your compliance.
Dimensioned detail: an electronic signature
Electronically signed by C. MoreauQuality assurance manager
Re-authentication: user ID and password re-entered for every signature (11.200).
Meaning: QA approval
Meaning displayed before signing, and shown on printouts (11.50).
2026-10-20 14:32:07 UTC
Server timestamp, in UTC.
9c2e4f71…7a90c4b1
Fingerprint of the signed content: the signature stays linked to the content it covers (11.70).
Signature registerNever rewritten
Signature register, printed with the record.
- Account lockout after repeated failures, failed signatures included; in the eQMS, administrators are alerted immediately (11.300).
- Sessions that expire on their own (11.10 (d)).
- Electronic signatures cover all six applications: the eQMS, the LIMS, the MES, the EMS, the VMS and the AMS, which signs the handover and return of its originals.
- Standard
- 21 CFR Part 11
- Issuer
- FDA
- Applications
- all six applications
Dimensioned detail: an audit trail entry
DEV-2026-0042Modification: criticality
What: the record and the action, logged by the system itself.
A. BenaliProduction manager
Who: an individual account, never reassigned.
2026-10-20 10:47:30 UTC
When: the server timestamp, in UTC.
Reason: affected batch identified
Why: the reason for the change.
Minor → Major
Before and after: the previous value remains viewable.
- § 9, audit trail: viewable, filterable, exportable.
- § 7, storage and backup: encrypted backups and tested restore for the eQMS; audit trail re-verified after a restore for the MES.
- § 10, change management: tracked versions, Change control in the eQMS.
- § 12, security: profiles, login and lockout logs.
- Standard
- EU GMP Annex 11
- Issuer
- European Commission, PIC/S
- Applications
- all six applications
Elevation: the V-model of the eQMS validation package
- eQMS validation package provided, in French and English, with a kit for your team.
- MES: category 5; it comes with a validation readiness checklist.
- LIMS and EMS: traceability matrices, from requirement to test.
- Automated tests on every change, in all applications: a change that fails is not deployed.
- Standard
- GAMP 5
- Issuer
- ISPE
- Applications
- all six applications
Schedule: nine principles, nine proofs
| Letter | Principle | Evidence in QaLyZa |
|---|---|---|
| Attributable | Every action carries the name of its author. | |
| Legible | Values, reasons and signatures shown in readable form, and exportable. | |
| Contemporaneous | Every action is timestamped when it happens. | |
| Original | Versions retained, approved documents never rewritten. | |
| Accurate | Checks at data entry and verified calculations. | |
| Complete | No deletion: a correction is added, with its reason. | |
| Consistent | Uniform numbering and timestamps. | |
| Enduring | Protected logs, encrypted backups. | |
| Available | Audit trails viewable, filterable and exportable at any time, including during inspections. |
- Standard
- ALCOA+
- Issuers
- FDA, MHRA, PIC/S
- Applications
- all six applications
Plan and readings: a monitoring point in grade A
- Rooms classified grade A to D; a grade change is signed and justified.
- Alert and action limits per monitoring point, with changes signed and kept on record.
- Excursion opened automatically as soon as a result or reading exceeds its limit; investigation (root cause and impact), then signed QA closure.
- Trends plotted with their limits; silent sensors flagged.
- Standard
- EU GMP Annex 1
- Issuer
- European Commission
- Application
- EMS
Software alone does not make an organization compliant: system validation, your procedures and your infrastructure all play a part. QaLyZa provides the mechanisms and documentation to support it.
Lya answers from your server
Lya is the eQMS assistant: a chat bubble where you ask questions about your records, in everyday language. It runs on your server; no data is sent to a third party.
- No training on your data.
- It respects each user's permissions.
- It cites the numbers of the records it relies on.
- It answers based on your records; it makes no quality decisions.
What is the status of DEV-2026-0042?
DEV-2026-0042, “Temperature deviation in the weighing area,” is at the Investigation stage. A CAPA is linked to it: CAPA-2026-0017, “Requalification of the weighing area probe.”
- Which deviations are overdue?
- Which CAPAs are linked to the weighing area?